Good Papers

GLINT: Sparsely Gated Vision-Language Alignment for Fine-Grained Radiology Representations

GLINT introduces sparse gating and dense feature regularization to learn fine-grained radiology vision-language representations that outperform baselines on classification, grounding, and zero-shot 3D CT segmentation.

Jonggwon Park, Seongeun Lee, Junhyun Park, Hannah Yun, Hyunwoong Kim, Sohyun Jeong, Hyewon Kang, Byungmu Yoon, Kyoyun Choi

Published 2026Sydney Poster Session 1 · Tue, Dec 8, 10:00 AM–1:00 PM local time · Hall 1-4arXiv ↗OpenReview ↗

86%
OverallMust read
?
OverallMust readVote to see the scoreThe exact score shows once you've voted, so every vote is your own call. The first half of each home page shelf shows its scores.
Readers
–

Only vote on papers you've read. Sign in with GitHub to vote.

AI panel14/20reviewers recommend it
lenient 5/5
medium 8/10
strict 1/5
AI panel?Vote to see what the 20 AI reviewers said

Abstract

Vision-language models (VLMs) for radiology have emerged as a scalable paradigm by leveraging image-report pairs naturally produced in clinical workflows. However, this pairing reveals a mismatch in scale: each finding occupies only a small region of the image, yet supervision is provided only at the global image-report level. This poses a central challenge: prior approaches spread weight densely across all patches rather than concentrating on the sparse subset relevant to a given query. To address this, we present GLINT (Gated Language-Image alignmeNT), a framework that explicitly models this sparse correspondence. On the alignment side, we introduce Sparsely Gated Alignment, a novel architecture in which a sigmoid gate over a separate gate embedding space activates only the patches relevant to each textual query, enforcing explicit sparsity. On the representation side, we add Dense Feature Regularization, which anchors the trainable encoder's intermediate features to a frozen self-supervised learning (SSL) teacher, preserving the fine-grained patch features that the gate relies on. The same recipe applies to both 2D chest X-ray (CXR) and 3D chest computed tomography (CT), built with DINOv3 and V-JEPA 2.1, respectively. GLINT enables zero-shot classification, grounding, and segmentation from free-text queries, and to our knowledge is the first to demonstrate zero-shot segmentation on 3D CT volumes without mask supervision. Notably, the most pronounced gains arise on zero-shot grounding and segmentation, where sparse, query-specific localization is required, consistent with our design intent. In downstream evaluation, GLINT outperforms both SSL encoders and medical VLMs on classification, report generation, and segmentation.